9 research outputs found

    HoughNet: neural network architecture for vanishing points detection

    Full text link
    In this paper we introduce a novel neural network architecture based on Fast Hough Transform layer. The layer of this type allows our neural network to accumulate features from linear areas across the entire image instead of local areas. We demonstrate its potential by solving the problem of vanishing points detection in the images of documents. Such problem occurs when dealing with camera shots of the documents in uncontrolled conditions. In this case, the document image can suffer several specific distortions including projective transform. To train our model, we use MIDV-500 dataset and provide testing results. The strong generalization ability of the suggested method is proven with its applying to a completely different ICDAR 2011 dewarping contest. In previously published papers considering these dataset authors measured the quality of vanishing point detection by counting correctly recognized words with open OCR engine Tesseract. To compare with them, we reproduce this experiment and show that our method outperforms the state-of-the-art result.Comment: 6 pages, 6 figures, 2 tables, 28 references, conferenc

    Polychromatic CT Data Improvement with One-Parameter Power Correction

    No full text
    Standard approaches to tomography reconstruction of the projection data registered with polychromatic emission lead to the appearance of cupping artifacts and irrelevant lines between regions of strong absorption. The main reason for their appearance is the fact that part of the emission with low energy is being absorbed entirely by high absorbing objects. This fact is known as beam hardening (BH). The procedure of processing projection data collected in polychromatic mode is presented; it reduces artifacts relevant to BH and does not require additional calibration experiments. The procedure consists of two steps: the first is to linearize the projection data with one-parameter power correction, and the second is to reconstruct the images from linearized data. Automatic parameter adjustment is the main advantage of the procedure. The optimization problem is formulated. The system flowchart is presented. The reconstruction with different powers of correction is considered to evaluate the quality reconstruction

    Enhanced Tomographic Sensing Multimodality with a Crystal Analyzer

    No full text
    This article demonstrates how a combination of well-known tools—a standard 2D detector (CCD (charge-coupled device) camera) and a crystal analyzer—can improve the multimodality of X-ray imaging and tomographic sensing. The use of a crystal analyzer allowed two characteristic lines of the molybdenum anode—Kα and Kβ—to be separated from the polychromatic radiation of the conventional X-ray tube. Thus, as a result of one measurement, three radiographic projections (images) were simultaneously recorded. The projection images at different wavelengths were separated in space and registered independently for further processing, which is of interest for the spectral tomography method. A projective transformation to compensate for the geometric distortions that occur during asymmetric diffraction was used. The first experimental results presented here appear promising

    Enhanced Tomographic Sensing Multimodality with a Crystal Analyzer

    No full text
    This article demonstrates how a combination of well-known tools—a standard 2D detector (CCD (charge-coupled device) camera) and a crystal analyzer—can improve the multimodality of X-ray imaging and tomographic sensing. The use of a crystal analyzer allowed two characteristic lines of the molybdenum anode—Kα and Kβ—to be separated from the polychromatic radiation of the conventional X-ray tube. Thus, as a result of one measurement, three radiographic projections (images) were simultaneously recorded. The projection images at different wavelengths were separated in space and registered independently for further processing, which is of interest for the spectral tomography method. A projective transformation to compensate for the geometric distortions that occur during asymmetric diffraction was used. The first experimental results presented here appear promising

    Tomographic Reconstruction: General Approach to Fast Back-Projection Algorithms

    No full text
    Addressing contemporary challenges in computed tomography (CT) demands precise and efficient reconstruction. This necessitates the optimization of CT methods, particularly by improving the algorithmic efficiency of the most computationally demanding operators—forward projection and backprojection. Every measurement setup requires a unique pair of these operators. While fast algorithms for calculating forward projection operators are adaptable across various setups, they fall short in three-dimensional scanning scenarios. Hence, fast algorithms are imperative for backprojection, an integral aspect of all established reconstruction methods. This paper introduces a general method for the calculation of backprojection operators in any measurement setup. It introduces a versatile method for transposing summation-based algorithms, which rely exclusively on addition operations. The proposed approach allows for the transformation of algorithms designed for forward projection calculation into those suitable for backprojection, with the latter maintaining asymptotic algorithmic complexity. Employing this method, fast algorithms for both forward projection and backprojection have been developed for the 2D few-view parallel-beam CT as well as for the 3D cone-beam CT. The theoretically substantiated complexity values for the proposed algorithms align with their experimentally derived estimates

    Monitored Tomographic Reconstruction—An Advanced Tool to Study the 3D Morphology of Nanomaterials

    No full text
    Detailed and accurate three-dimensional (3D) information about the morphology of hierarchically structured materials is derived from multi-scale X-ray computed tomography (XCT) and subsequent 3D data reconstruction. High-resolution X-ray microscopy and nano-XCT are suitable techniques to nondestructively study nanomaterials, including porous or skeleton materials. However, laboratory nano-XCT studies are very time-consuming. To reduce the time-to-data by more than an order of magnitude, we propose taking advantage of a monitored tomographic reconstruction. The benefit of this new protocol for 3D imaging is that the data acquisition for each projection is interspersed by image reconstruction. We demonstrate this new approach for nano-XCT data of a novel transition-metal-based materials system: MoNi4 electrocatalysts anchored on MoO2 cuboids aligned on Ni foam (MoNi4/MoO2@Ni). Quantitative data that describe the 3D morphology of this hierarchically structured system with an advanced electrocatalytically active nanomaterial are needed to tailor performance and durability of the electrocatalyst system. We present the framework for monitored tomographic reconstruction, construct three stopping rules for various reconstruction quality metrics and provide their experimental evaluation

    Reprojection-Based Numerical Measure of Robustness for CT Reconstruction Neural Network Algorithms

    No full text
    In computed tomography, state-of-the-art reconstruction is based on neural network (NN) algorithms. However, NN reconstruction algorithms can be not robust to small noise-like perturbations in the input signal. A not robust NN algorithm can produce inaccurate reconstruction with plausible artifacts that cannot be detected. Hence, the robustness of NN algorithms should be investigated and evaluated. There have been several attempts to construct the numerical metrics of the NN reconstruction algorithms’ robustness. However, these metrics estimate only the probability of the easily distinguishable artifacts occurring in the reconstruction. However, these methods measure only the probability of appearance of easily distinguishable artifacts on the reconstruction, which cannot lead to misdiagnosis in clinical applications. In this work, we propose a new method for numerical estimation of the robustness of the NN reconstruction algorithms. This method is based on the probability evaluation for NN to form such selected additional structures during reconstruction which may lead to an incorrect diagnosis. The method outputs a numerical score value from 0 to 1 that can be used when benchmarking the robustness of different reconstruction algorithms. We employed the proposed method to perform a comparative study of seven reconstruction algorithms, including five NN-based and two classical. The ResUNet network had the best robustness score (0.65) among the investigated NN algorithms, but its robustness score is still lower than that of the classical algorithm SIRT (0.989). The investigated NN models demonstrated a wide range of robustness scores (0.38–0.65). Thus, in this work, robustness of 7 reconstruction algorithms was measured using the new proposed score and it was shown that some of the neural algorithms are not robust

    Artifacts suppression in biomedical images using a guided filter

    No full text
    Despite significant progress in computer vision, pattern recognition, and image analysis, artifacts in imaging still hampers the progress in many scientific fields relying on the results of image analysis. We here present an advanced image-based artifacts suppression algorithm for high-resolution tomography. The algorithm is based on guided filtering of a reconstructed image mapped from the Cartesian to the polar coordinates space. This postprocessing method efficiently reduces both ring- and radial streak artifacts in a reconstructed image. Radial streak artifacts can appear in tomography with an off-center rotation of a large object over 360 degrees used to increase the reconstruction field of view. We successfully applied the developed algorithm for improving x-ray phase-contrast images of human post-mortem pineal gland and olfactory bulbs
    corecore